- Issue
- Journal of Siberian Federal University. Engineering & Technologies. 2026 19 (5)
- Authors
- Kilichov, Orifjon G.; Muzafarov, Shavkat M.; Ruzikulov, Z. Z.
- Contact information
- Kilichov, Orifjon G. : Tashkent Institute of Irrigation and Agricultural Mechanization Engineers (Tashkent, Republic of Uzbekistan); ; Muzafarov, Shavkat M.: Tashkent Institute of Irrigation and Agricultural Mechanization Engineers (Tashkent, Republic of Uzbekistan); Ruzikulov, Z. Z.: Tashkent Institute of Irrigation and Agricultural Mechanization Engineers (Tashkent, Republic of Uzbekistan)
- Keywords
- ozone; electrosynthesis; sinusoidal; pulse voltages; dielectric barrier and amplitude
- Abstract
The article provides information about the existing methods of ozone electrosynthesis and identifies their drawbacks. Based on the analysis of processes in the power supply circuit of ozone generators with sinusoidal and pulse voltage of high duty cycle, the possibility of reducing losses and increasing efficiency, increasing the yield of ozone, is substantiated. The distribution of the electric field intensity over the elements of a cylindrical ozone generator was analyzed when it was powered by a sinusoidal and periodic pulse voltage with a duty cycle of more than 5. It was found that it is possible to generate ozone without pre-cooling and drying the air, or cooling the dielectric barrier with running water
- Pages
- 566–574
- EDN
- WNGVBN
- Paper at repository of SibFU
- https://elib.sfu-kras.ru/handle/2311/159297
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).