- Issue
- Journal of Siberian Federal University. Engineering & Technologies. 2021 14 (4)
- Authors
- Sokolov, Nikita Yu.; Kulagin, Vladimir A.; Nesterov, Dmitry A.
- Contact information
- Sokolov, Nikita Yu.: Information Satellite Systems – Reshetnev Company Zheleznogorsk, Russian Federation; Kulagin, Vladimir A.: Siberian Federal University Krasnoyarsk, Russian Federation;; Nesterov, Dmitry A.: Institute of Computational Modeling SB RAS Division of FRC KSC SB RAS Krasnoyarsk, Russian Federation
- Keywords
- flat heat pipe; heat pipe system; cooling of electronics; high thermal power density
- Abstract
We report on the results of optimizing a single flat heat pipe into an arrangement of heat pipes. A comparison is drawn at the same temperatures and occupied volumes and for a specific maximum temperature of radio-electronic devices. The end result of our studies is that the limiting heat transfer capacity has been found for a single heat pipe and two- and three-level heat pipe assemblies with various heat transfer media. Versatility of the mathematical model enhanced by the optimization method has been proved
- Pages
- 363–377
- DOI
- 10.17516/1999-494X-0317
- Paper at repository of SibFU
- https://elib.sfu-kras.ru/handle/2311/141361
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).