Journal of Siberian Federal University. Engineering & Technologies / The Hydraulic Characteristics of the Reactor – Clarifier Including Ripple Contact Mass Particles

Full text (.pdf)
Issue
Journal of Siberian Federal University. Engineering & Technologies. 2017 10 (1)
Authors
Skolubovich, Yuri L.; Soppa, Mikhail S.; Sineeva, Natalya V.; Skolubovich, Alexey Y.
Contact information
Skolubovich, Yuri L.: Novosibirsk State University of Architecture and Civil Engineering (Sibstrin) 113 Leningradskay, Novosibirsk, 630008, Russia; ; Soppa, Mikhail S.: Novosibirsk State University of Architecture and Civil Engineering (Sibstrin) 113 Leningradskay, Novosibirsk, 630008, Russia; ; Sineeva, Natalya V.: Novosibirsk State University of Architecture and Civil Engineering (Sibstrin) 113 Leningradskay, Novosibirsk, 630008, Russia; Skolubovich, Alexey Y.: Novosibirsk State University of Architecture and Civil Engineering (Sibstrin) 113 Leningradskay, Novosibirsk, 630008, Russia;
Keywords
simulation; fluidized layer; the grain loading; the self-oscillations; the loss of pressure; the hysteresis
Abstract

The paper considers the model of hydrodynamic processes in the reactor – clarifier that uses filtering technology in a fluidized layer. Dynamic load ripple particles lead to a substantial increase in clean suspensions from the impurities. Simulation allows to determine the loss of pressure in different parts of the structure. The free flow of power component costs associated with the hydrostatic pressure and viscous friction forces in laminar flow. In the fluidized layer these costs are due to the grain loading parameters: diameter, density, porosity. On the basis of the proposed model of self-oscillatory movement of grain loading obtained relations for estimation of particle ripple effect on the value of head loss. Therefore necessary to average power in increments of hydraulic gradient is established. Analysis of hysteresis phenomena in various design modes spend, due to the fact that the height of the weighted layer is not a unique function of supplying treated water rate. It is shown that the occurrence of the hysteresis loop can be connected with the capture of the self-oscillation frequency of movement of the contact mass particles

Pages
36-43
Paper at repository of SibFU
https://elib.sfu-kras.ru/handle/2311/30789

Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).